The vibrating rod for sanitary applications can be installed through a top or side mount for high, mid, or low-level detection of a wide variety of dry and bulk powder materials, including extremely light, fluffy inventory. The vibrating rod features a two-inch stainless steel sanitary fitting for use with the tri-clover style clamp that removes easily for cleaning and sanitation. The rod is ideal for food and pharmaceutical processing or for use with any other materials that require sanitary conditions.
Power Requirements: Wide range 20-250V AC/DC
Relay: DPDT
Time Delay: 1 second from stop of vibration, 2 to 5 seconds for start of vibration
Ambient Temp: -4°F to +140°F (-20°C to +60°C)
Process Temp: To 176°F standard (80°C); to 284°F high temp (140°C)
Pressure: 145 psi
Enclosure: Die cast aluminum, NEMA 4, 5 & 12
Probe: 304 stainless steel, 11.81”” insertion length
Fitting: 2” sanitary 316 SS fitting with tri-clamp
Mounting: 1-1/2” NPT
Material Densities: From 1.25 lb./cu. ft.