Features of BinMaster Capacitance Probes:      


  • Electronic stability that will firmly hold calibration
  • Temperature stable from -40°F to +180°F
  • Incorporate a unique discharge time constant detector circuit which allows sensing capacitance changes less than 1 picofarad
  • PROCAP series probes operate at approximately 6 kHz and do not generate radio frequencies -- we are true capacitance
  • Four level of static safeguards; (1) Static Drain (2) Gas discharge tube that does not allow voltage to rise above a certain level (3) By-Pass Capacitance on input passes a fast impulse to ground (4) Current Limiting series resistance on probe
  • Fail Safe fault detection monitoring
  • The "Quick Set" calibration feature allow for simple setup and calibration of the unit to achieve low, medium, or high sensitivity settings. Units are calibrated with the probes uncovered.
  • Multiple power capabilities
  • New stronger 5/8" stainless steel probe
  • 3/4" NPT and 1 1/4" NPT mounts standard on all 5/8"probe units.
  • PROCAP series feature the PRO-Shield to guard against false indications from material side wall buildup on the sensing probe
  • Standard Delrin insulated sleeve probes that are highly abrasion resistant and inexpensive to replace should they wear out. Allows the probe to function in both dry solid or liquid applications. These sleeves also give us the coated probe necessary for explosion proof and food grade applications.
  • Multiple power pack, probe and fitting options
  • All components designed for industrial application

Contact Us

 

Probe Options
(click Image to View)

All Probes