The
Pro Remote capacitance sensor is specially designed
for high temperature, vibration, or hazardous
applications. This model features remote electronics
located in a separate housing. Depending upon
necessary sensitivity, this allows the sensor's
electronics to be safely mounted up to 75' from
the sensing probe and hostile environment.
Features
-
"Quick Set" simple calibration, adjustable sensitivity
to <1 picofarads
-
Pro Shield protects against false readings due
to coating or material buildup
-
Operates below RF range for stable calibration
and protection from RF interference
-
Fail-Safe, switch selectable high/low
-
Adjustable time delay to 10 seconds
- LED
indicates material in contact with probe
|
PRO Remote 75 |
Specifications: PRO Remote
|
| Power
Requirements: |
115/230
VAC
50/60 Hz ± 15%, 5VA |
| Output
Relay: |
DPDT
10 Amp at 250 VAC
STATUS Contacts: 3 Amps 240 VAC |
Ambient
Temperature
Electronics:
Probe: |
-40°
to +185°F (-40° to +85°C)
+250°F Delrin, +500°F Teflon |
| Pressure: |
500
PSI, ¾" Mount |
| Sensitivity
Setting: |
Adjustable
Sensitivity to < 1 Picofarad |
| Calibration: |
"Quick
Set" Course/Fine
Single Turn Potentiometers |
| Fail-Safe: |
Switch
Selectable High/Low |
| Time
Delay: |
Adjust
.25 to 10 Seconds |
Enclosure
Probe:
Electronics: |
Cast
Aluminum, Bolt-on Cover
USDA Approved Finish
Plastic |
| Mounting: |
1
¼" NPT or ¾" NPT 316 SS |
| Pro
Shield: |
Compensates
For Material Build-up On Sensing Probe |
Approval
Ratings
Probe:
Electronics: |
NRTL/C
NEMA 4X, 5 and 12
Intrinsically Safe
Class I Group C & D
Class II Group E, F & G
NEMA 4X, 5 and 12 |
| Status
Indicator: |
Internal
LED Indicates Material
In Contact With Probe |
| Probe
Options: |
Standard,
Flush Mount, Flexible Extension, Teflon Sleeved,
Extended Shield, Stubby |